Abstract

The work was devoted to development of the experimental unit for measurement and comparison of tritium permeation rates through bare and protected martensitic steel tubes. Both out-of-pile deuterium gas driven experiments and in-pile tritium permeation experiments were performed. The permeation reduction factor was estimated to be not less than 50 in both series. A few in-pile experiments of 6 h of duration each were performed in a high flux reactor. No degradation of the protection layer was observed for this period.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.