Abstract

Case histories of 39 patients who underwent tricuspid valve replacement with the St. Jude Medical prosthesis between June 1979 and August 1992 were reviewed in March 1993. The average patient age at the time of the operation was 46 +/- 11 years (range from 17 to 68 years). Concomitant mitral and/or aortic valve replacements were performed in 30 patients. All patients were given warfarin to maintain thrombotest between 10% to 25%. This number was between 2.8 to 1.6 times the control value in the International Normalized Ratio of prothrombin time. Three operative deaths occurred (7.7%). Among six late deaths, two patients died suddenly of unknown causes, and the remaining patient deaths were not valve-related. The actuarial survival rate at 14 years was 54.7%. Valve thrombosis occurred in one patient and was successfully treated with intravenous urokinase. This was the only valve-related complication (0.67%/patient-year). No reoperations were necessary in the tricuspid position. In conclusion, the St. Jude Medical valve is our choice of prosthesis for tricuspid valve replacement in adult patients who can receive proper anticoagulation therapy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.