Abstract

A study was conducted on 20 patients who underwent tricuspid valve replacement (TVR) with the St. Jude Medical (SJM) valve. Isolated TVR was performed on 9 patients, and additional mitral, or mitral and aortic valve replacements were performed on 11 patients. Four patients (20%) died in the early postoperative period, but there were no deaths related to the SJM valve in the tricuspid position. The mean follow-up period of the 16 survivors was 74.4 months, and there have been no deaths during the follow-up period. The postoperative actuarial survival rate was 80%, 10 years after surgery. Three patients, representing 0.25%/patient-months, developed valve thrombosis, the valve thrombosis-free rate being 72.8%, 10 years after surgery, while entrapment of a leaflet by endothelial pannus was found in one patient, representing 0.08%/patient-months. Thus, the incidence of all prosthetic valve-related complications was 0.34%/patient-months, and the postoperative complication-free rate was 65.3%, 10 years after surgery. The medium-term follow-up study of TVR with the SJM valve revealed no prosthetic valve-related deaths and a relatively low incidence of prosthetic valve-related complications. However, as with other mechanical valves, valve thrombosis was a major risk posed by the SJM valve in the tricuspid position.