Ultrasonic distance gauges were implanted in the left ventricle of dogs to measure continuously ventricular wall thickness and small axis diameter. A miniature transducer was implanted to measure intraventricular pressure. The circumflex artery could be occluded mechanically to mimic coronary spasm. Recordings were made on tape after allowing eight days post-operative recuperation. The taped signals were digitised and processed to show graphical relationships between selected variables. We found that triaxial (3D) graphics greatly enhanced our ability to interpret moment by moment changes in these relationships, and recommend this procedure to others.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.