Abstract

After 2 years of operation in the waste water treatment plant of the El Aguila brewery, the performance of the ANAFLUX fluidized bed reactors could be examined. For the treatment of the brewery effluent, an acidification tank is required upstream of the reactors so that high COD loadings (up to 60 Kg COD/m3/day) could be applied to the fluidized beds for hydraulic retention times of 2 hours. The wide variations in the pollutant load do not have any irreparable effects on the efficiency of the purification process. Efficiency of the acidification and methanization line reaches 80% of soluble COD and 72% of total COD. An additional aerobic finishing treatment further increases the levels of efficiency (less than 50 mg/l COD at the plant outlet).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.