Abstract

Treatment of wastewater from a tannery in Greater Ho Chi Minh City (Vietnam) was investigated on a pilot scale. After pre-treatment by the tannery that included batch-coagulation and sedimentation, the wastewater was treated by dissolved air flotation, a membrane bioreactor (MBR) and granular activated carbon (GAC) for polishing the MBR effluent. The average removal efficiency for organic substances in the MBR was 81% while total nitrogen could only be removed by 36%. The performance of the GAC column could be successfully predicted using adsorption parameters determined in laboratory experiments. A larger proportion of the organics in the MBR effluent was only weakly adsorbable, therefore the usable carbon capacity was limited as confirmed by the modelling approach. The results were used to outline the size of a technical plant with a volumetric loading rate of 3 kg COD/(m3*d) for the MBR and a specific carbon demand of about 1.8 kg/m3.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.