Abstract

In this article, coke plant wastewater was treated by a simultaneous nitrifying and denitrifying (SND) fixed biofilm hybrid system. The results showed that suitable parameters of the system were important for the performance of the bio-degradation system. The chemical oxygen demand (COD) removal efficiency in this system was satisfactory, higher than 94%, and ammonia nitrogen was higher than 95%. The effluent COD concentration could meet the discharge standard, except for very few situations. The results showed that a sufficient carbon source was important for making ammonia nitrogen concentration meet the discharge standard. Then the TN removal efficiency in this system can be brought higher than 94%. Dissolved oxygen (DO) is very important to the performance of the SND bio-degradation system, and the suitable DO is about 3.5–4.0 mg/L at the forepart of reactor. In addition, the performance of the system was almost not affected by pH value. The results show that the system is feasible to treat coke plant wastewater.

Full Text