Abstract

Five groups of vibration experiments were carried out on the 6.8 grades and M20 bolts and nuts that used on transmission tower. The test result shows that the basic way to improve the anti-loosening property was increasing the initial preload. Both increasing initial torque and appending lubrication can obviously increase the initial preload, however appending lubrication may reduce it's anti-loosening property under the situation of same preload. In the vibrating process the second stage plays a decisive role for anti-loosening property, it can be expressed as reduced rate “K” of the preload.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.