Abstract

This study investigates using concrete infilled steel tubes as hybrid nodes for discrete reticulated shell structures under compressive loading transverse to the tube axis. Three configurations were tested: empty, plain concrete infilled and polypropylene fiber-reinforced concrete infilled steel tubes. Displacement-controlled loading was applied through welded steel plates. Simplified beam theory models and nonlinear finite element analysis were used to evaluate the structural behavior. The concrete infilled steel tube specimens had higher stiffness and load-bearing capacity than the empty ones. The structural behavior of the concrete infilled specimens could be split into pre- and post-split-tensile cracking phases. No significant difference was found between the plain and fiber-reinforced concrete specimens under loads up to 1500 kN, which was the load limit of the testing machine. An additional fiber-reinforced concrete specimen, tested on a higher capacity machine, had a load-bearing capacity of 2400 kN and exhibited ductile failure.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.