Many robotic mitral surgeons utilize right thoracotomy with transthoracic clamping of the aorta, while a smaller number employ a port-only endoscopic approach with endoaortic balloon occlusion of the aorta. We present our technique for a port-only endoscopic robotic approach with transthoracic clamping. From July 2019 through December 2022, 133 patients underwent port-only endoscopic robotic mitral surgery with transthoracic clamp aortic occlusion and antegrade cardioplegia. Perfusion was through the femoral artery in 101 patients (76%) and axillary in 32 patients (24%). Clamp technique involved placing the clamp at the mid-ascending aorta, dynamic valve testing to 90 mm aortic root pressure, and closure of the cardioplegia cannula site prior to clamp removal. Indications for clamp utilization over balloon occlusion included both balloon supply issues and aortoiliac anatomy. Mitral repair was performed in 122 patients (92.7%) and mitral valve replacement in 11 patients (8.3%). Mean aortic occlusion time was 92 ± 21.4 min. Mean time from left atrial closure to clamp removal was 8.7 (7.2 to 12.8) min. There were no injuries to the aorta or surrounding structures, mortality, strokes, or renal failure. For robotic teams with endoaortic balloon capability, this technique may be useful in certain patients with aorto-iliac pathology or limited femoral artery access. Alternatively, robotic teams who employ transthoracic aortic clamping through a thoracotomy may find this technique useful to transition to a port-only endoscopic approach.