Abstract
AbstractThermal characteristic is one of the key performances of dry‐type on‐board traction transformer (D‐OBTT), which directly affects the operation safety of the new generation electric multiple units. However, due to the particularity of train‐induced wind cooling mode of D‐OBTT, the existing efficient thermal modelling methods cannot be used under fluctuating air velocity and load. A time‐saving transient thermal model for D‐OBTT is proposed. First, the framework of the transient thermal network model (TTNM) is proposed considering the coexistence of non‐fully and fully developed state of the train‐induced wind and the addition heat flow in the solid domain. Then, a novel formula for calculating the length of non‐fully developed section considering the geometric dimensions and heat flux density is proposed based on computational fluid dynamics (CFD) parametric sweeps for the first time. The accuracy of TTNM is validated by a D‐OBTT experimental setup, and the time consumption is significantly reduced compared with CFD.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.