Abstract
A transient thermal network model is utilized to design and evaluate the transient thermal characteristics of power modules. Static test method identifies the transient thermal network model from the time response of the junction temperature, which is obtained by using the temperature dependency of I-V characteristics for power devices. This paper experimentally evaluates the effect of the sampling frequency and the resolution of the AD conversion on the accuracy of the obtained transient thermal network model. The high sampling frequency and the high resolution in the obtained time response of the junction temperature enable to clearly identify the transient thermal network model of the power module with the direct bonding copper substrate.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.