Abstract
High temperature heat pipes are effective devices for heat transfer, which are characterized by remarkable advantages in conductivity, isothermality and passivity. It is of significance to apply heat pipes on new concept passive residual heat removal system (PRHRS) of molten salt reactor (MSR). In this paper, the transient performance of high temperature sodium heat pipe is simulated with numerical method in the case of MSR accident. The model of the heat pipe is composed of three conjugate heat transfers, i.e. the vapor space, wick structure and wall. Based on finite element method, the governing equations and boundary conditions are solved by using FORTRAN code to acquire the profiles of the temperature, velocity and pressure for the heat pipe transient operation. The results indicated that high temperature sodium heat pipe had a good operating characteristic and removed the residual heat of fuel salt rapidly under the accident of MSR.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have