Abstract
Fast Cut Back (FCB) technology of large thermal power plant can maintain the isolated operation of auxiliary power after the units are disconnected from the power grid. FCB unit can immediately cut off all external loads without turbine or boiler shutdown in case of large power grid failure, and supply power immediately as the external power grid fault eliminated, which has a very important impact on improving the stability and the recovery speed of the power grid system. Therefore, it is necessary to establish a dynamic mathematical model of thermal power plant to simulate FCB process. According to the principle of mass and energy balance, a dynamic mathematical model of 1050 MW thermal power unit was established. The model considered the change trends of main steam pressure and temperature caused by the action of main steam valve and high-pressure (HP) bypass valve in FCB process, and the action characteristics of safety valve and pressure control valve (PCV) valve in FCB system. This model provides a reference for the simulation and control of FCB process in thermal power unit.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.