Abstract

In this paper, the time domain characters of the response of twisted wire pairs (TWPs) excited by the high-altitude electromagnetic pulse (HEMP) have been proposed. The finite different time domain transmission line model (FDTD-TLM) method, which we have proposed previously, is used to calculate the terminal response of TWP. It shows that the time domain response includes two stages: The transient stage and damped stage. The transient stage is the key point of the coupling and protecting research. The influence factors of the transient stage have been analyzed. In the end, we obtain the changes of the induced voltage when the incident wave parameters and TWP parameters change.