Abstract

A transient and static hybrid-triggered active clamp is proposed in this paper. By skillfully incorporating different detection mechanisms, the proposed clamp achieves enhanced static electrical overstress protection capability over the transient one. Furthermore, the proposed clamp achieves improved electrostatic discharge reaction speed in both human body model and charged device model events over the static one. Moreover, the superior transient-noise immunity of the proposed clamp over traditional transient ones is essentially revealed in this paper. The proposed clamp is successfully verified in a 65-nm bulk CMOS process. In addition, the design flexibility of the proposed clamp for other processes is also deeply discussed in this paper.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.