Abstract

Objective: To test a simple method of intrapartum amnioinfusion to replace amniotic fluid during labor in cases of prolonged labor and severe variable fetal heart rate decelerations or thick meconium. Study design: We conducted a prospective study of intrapartum amnioinfusion in sixteen consecutive patients. A simple transcervically placed Foley bladder catheter was used for intrauterine infusion of saline solution, while monitoring was performed by external cardiotocography. Results: In twelve patients, catheter placement was easily performed; the remaining four required stabilization by a mandrel for insertion. Amnioinfusion was effective in ten out of thirteen patients for relief of fetal heart rate anomalies. No complications were observed; all had good neonatal outcome. Conclusions: In our small, uncontrolled study, this amnioinfusion method proved to be a simple, inexpensive, effective and safe technique for the relief of severe heart rate anomalies in prolonged labor.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.