Abstract

To evaluate the effect of end-tidal carbon dioxide (EtCO2) detection for location of the leading bronchus in patients with pneumothorax. Transbronchoscopic EtCO2 detection was performed in 4 patients with intractable pneumothorax in whom transbronchoscopic balloon detection failed to localize the leading bronchus. A specific bronchus was suspected to be the leading bronchus when its EtCO2 value was significantly lower than that of the main bronchus of the affected lung. After the pleural air leakage was successfully sealed by bronchial occlusion of the suspected bronchus, the EtCO2 was confirmed to indicate the leading bronchus. Transbronchoscopic EtCO2 detection successfully located the leading bronchus in all 4 patients. Transbronchoscopic EtCO2 detection is a new method of locating the leading bronchus in patients with intractable pneumothorax.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.