Abstract
Photothermal deflection spectroscopy is a method used indirectly to measure optical absorption of a sample. Different techniques can be employed to measure the amount of deflection, hence evaluate optical absorption of sample. This work investigates an alternative method both in principle and technique to measure sample’s optical absorption. The new method employed for the first time, relies on the simple idea of light beam deflection from the medium under investigation as a result of change in the index of refraction in its vicinity. The amount of deviation executed by the deviated beam is estimated using new technique that is used for the first time in deflection spectroscopy. As the deviated beam is allowed to pass through a single slit, the value of beam deflection is estimated from the resulting diffraction pattern, i.e. indicating the value of changes taking place in the sample and or measure sample’s optical absorption. The new detection technique used in the estimation of probe beam deflection was also applied in photothermal spectroscopy. Results from both methods were compared and revealed the ease of use of the new method, in addition it cuts cost and experimental efforts although its sensitivity is less than the conventional photothermal method.
Highlights
In photothermal deflection spectroscopy, sample under investigation undergoes a photo-excitation, i.e. optical absorption, which subsequently causes a change in state of the sample and a thermal response
The amount of deviation executed by the deviated beam is estimated using new technique that is used for the first time in deflection spectroscopy
As the deviated beam is allowed to pass through a single slit, the value of beam deflection is estimated from the resulting diffraction pattern, i.e. indicating the value of changes taking place in the sample and or measure sample’s optical absorption
Summary
Sample under investigation undergoes a photo-excitation, i.e. optical absorption, which subsequently causes a change in state of the sample and a thermal response. In regular optical absorption spectroscopy, the intensity of the exciting light beam and passing through the sample is monitored and compared with the intensity of light beam before it enters the sample. In photothermal spectroscopy, the transmission of light is not used in measuring, and instead, sample heating, which is a direct consequence of optical absorption, is what is studied by measuring the value of deflection suffered by a probe beam. Photothermal deflection spectroscopy (PTDS) is widely used in many applications for example in the investigations of thermal diffusivity of bulk solids and thin films [4], measurements of low absorption coefficients [5], temperature measurements in flame by photothermal spectroscopy was used [6,7], study of solids [8] and electrochromism of synthetic metals [9]
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have