Abstract
A simple and sensitive liquid chromatographic method is described for the determination of ethosuximide in human plasma, as a highly sensitive derivative. Ethosuximide spiked in plasma was extracted with toluene and derivatized with a chemically removable derivatizing reagent, 2-(2-naphthoxy)ethyl 2-[1-(4-benzyl)piperazyl]ethanesulfonate, in a homogeneous system, using magnesium oxide as base catalyst. The resulting derivative was separated on a LiChrospher diol column with 1.2% isopropanol in n-hexane as the mobile phase and using coumarin as the internal standard. Several parameters affecting the extraction/derivatization of ethosuximide from spiked plasma were investigated. The linear range for the determination of ethosuximide in spiked plasma was over 30–700 nmol/ml. For ethosuximide in plasma, the detection limit (signal-to-noise ratio=3; sample size, 10 μl) was about 9 pmol; the relative standard deviation was 6.4% for intra-day assay ( n=6) and 9.2% for inter-day assay ( n=6) and the relative recovery was found greater than 94%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Chromatography B: Biomedical Sciences and Applications
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.