Abstract

In this work, a biodegradable poly(ethylene glycol)-poly(epsilon-caprolactone)-poly (ethylene glycol) (PEG-PCL-PEG, PECE) triblock copolymer was successfully synthesized, which was flowing sol at low temperature and turned to nonflowing gel at body temperature. The toxicity evaluation of PECE hydrogel as a potential in situ sustained opthalmic drug delivery system was performed, including the biodegradability of PECE hydrogel in the eye, its effect on cultured human lens epithelia, intraocular pressure, and ocular tissues. The results indicated that the prepared PECE hydrogel was biocompatible and biodegradable despite of temporary elevated intraocular pressure and slight corneal endothelial damage at specific concentration. Therefore, PECE hydrogel may be a safe candidate for sustained ophthalmic drug delivery system.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.