Abstract

A 2D axisymmetric two-phase model was developed to study the effect of an arc impingement on the liquid metal inside an electric arc furnace. In addition to the arc flow dynamics, the model covered the heat transfer and magneto hydrodynamics of the arc and the liquid metal. Through a parametric study, three different parameters were considered to predict the most important factors affecting the arc and overall behaviour of the process: the arc gap, the density of the gas, and the total electric current. Understanding the effect of these parameters can show the key factors altering the arc dynamics. The study showed that the total applied current was the most important parameter that influenced the impingement depth and mixing of the liquid metal. The depth of the impingement and strength of the mixing of the liquid bath were directly proportional to the current applied in the furnace. The initial arc gap distance was found to be crucial for sustaining a continuous and stable arc. The value of the gas density was very important for the velocity profile; however, it had no significant effect on the impingement depth. This showed that a constant density could be used instead of a varying gas density with temperature to increase the computational efficiency. The study assessed the effects of the aforementioned factors on the arc impingement depth, velocity magnitude, and arc stability. The conclusions acquired and challenges are also presented.

Highlights

  • The first use of an electric arc furnace (EAF) was in the 19th century

  • A 2D axisymmetric two-phase model was developed to study the effect of an arc impingement on the liquid metal inside an electric arc furnace

  • The value of the gas density was very important for the velocity profile; it had no significant effect on the impingement depth

Read more

Summary

Introduction

The first use of an electric arc furnace (EAF) was in the 19th century. A direct current (DC) in an EAF was first used in the late 1800s, the major development and industrial use was focused on alternating current (AC) furnaces. This was driven by the better efficiency and power transmission of AC power. The shift toward DC furnaces is because they are believed to have a better power efficiency, less electrode consumption, and a lower level of noise. As a result of the increasing demand for DC arc furnaces in industry, further improvements in their design and a better understanding of the method of operations are required. A typical configuration of the DC-EAF entails a large liquid metal bath cylinder

Objectives
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.