Abstract

Total oxidisable precursor assay (TOP assay) can degrade and convert “unknown” per- and polyfluoroalkyl substances (PFAS) to detectable PFAS. However, the detailed degradation pathway is still not known, particularly when the TOP assay is applied to analyse complex samples such as aqueous film-forming foam (AFFF). To gain insights into the pathway and the effectiveness of the TOP assay, several “known” compounds are first tested as controls, including sodium dodecyl benzene sulphate (SDBS), perfluorooctanoic acid (PFOA), perfluorooctanesulfonic acid (PFOS). Secondly, the test is expanded to several PFAS precursors such as 6:2 fluorotelomer sulfonate (6:2 FTS), 8:2 fluorotelomer sulfonate (8:2 FTS), and a cationic surfactant N-ethyl-N-(2-hydroxyethyl) perfluorooctyl sulfonamide (EtFOSE). Thirdly, the TOP assay is used to test “unknown” PFAS samples that have been previously used as AFFF in Australia. The degradation products are monitored, to compare the mass balance and propose the degradation pathway. While HPLC-MS/MS is typically employed to detect the individual TOP assay products, most of which are perfluoroalkyl carboxylic acids (PFCA), an app-based smartphone sensor can also provide semi-quantitative results as a sum. Overall, the results indicate the effectiveness of the TOP assay to assess the presence of PFAS precursors in the AFFF samples, with some variations in the end products. Recommendations for enhancement of the TOP assay are also provided.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call