Abstract
Intermetallic titanium aluminide samples implanted with fluorine using plasma immersion ion implantation were investigated after high-temperature exposure for short times at 500 and 900 °C in air by ToF-SIMS as a surface analytical method. The ToF-SIMS method was applied in order to obtain information regarding the location of fluorine with respect to the oxide layer formed and the substrate after ion implantation and after high-temperature exposure, respectively. The aim of the present work was to obtain further insight into the mechanisms active during the initial stages of oxidation. The scale structure in the initial oxidation phase consists of titanium and aluminum oxides/fluorides/oxyfluorides. The arrangement of their layered structure can be interpreted according to their thermodynamic stabilities in the partial pressure gradient of oxygen over the scale and according to the metal activities and the presence of fluorine at the metal/scale interface.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.