Abstract

The maximum transient voltage of a MOSFET device is one of the key parameters for power applications. Therefore, transmission line pulse (TLP) characterization is used to assess this. TLP measurements on large gate width devices are difficult to perform due to gate oscillations. In this paper, a method to avoid oscillation when measuring large gate width devices is presented. Device simulations are presented showing gate side oscillation triggered by the rising edge of the 100 ns TLP pulse. Adding a resistor in series with the gate largely damps the oscillation. Comparison between system level simulation and captured TLP waveforms is done and the correlation is discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.