A mixed lumped-distributed model of a transmission line pulse (TLP) measurement setup is presented. The model of the TLP generator, rise-time filter and probing needles is extracted based on the TLP measurements of open, short and matched loads in the voltage range up to 650 V. A behavioural model of an ESD protection device is built based on the measured quasi-static TLP characteristic and on the small-signal S-parameters of the device. The presented TLP generator and DUT models are verified by comparing the measured time-domain waveforms with the simulation results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.