Abstract
In initializing a transmission line matrix (TLM) diffusion model it is necessary to consider both initial concentration (temperature) and initial flow. As usual, only one of them is given; an auxiliary formula is necessary to calculate the distribution for the first time step. It has been shown that the standard formula may introduce additional numerical errors (International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 1993; 6:135; International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 1993; 6:161) and that these errors can persist over many time steps. In this paper, we show how an initial modification to the normal TLM algorithm can remove such errors, and we demonstrate the method by applying it to a two-dimensional TLM heat diffusion model for a copper plate. Copyright © 2002 John Wiley & Sons, Ltd.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Numerical Modelling: Electronic Networks, Devices and Fields
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.