Abstract
Methyl, ethyl,iso-propyl, allyl,n-butyl,t-butyl,iso-amyl, cyclohexyl and benzyl xanthates of potassium have been determined by titrating with iodine and bromine cyanides in aqueous medium at pH 5.0–5.4 and in acetonitrile, ethanol, 1 ∶ 1 ethanol-carbon tetrachloride mixture and ethyl acetate media visually and/or potentiometrically. The xanthates react in the molar ratio 2 ∶ 1 with these oxidants and are oxidised to dixanthogen. The potentiometric titrations of BrCN with xanthates, unlike with other reductants, are possible in aqueous medium even in absence of iodide which has to be added in visual titrations because of a lack of some specific indicator. The titrations are rapid, simple, accurate and reversible and as little as 1 mg can be determined in aqueous or acetonitrile medium.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.