Abstract

<p><span style="font-size: medium;"><span style="font-family: 宋体;">In wireless sensor networks, for improving the time synchronization perfromance of online monitoring and application of ZigBee protocol, a scheme is designed. For this objective, first of all, the ZigBee protocol specification is summarized, a profound analysis of the hardware abstraction architecture of TinyOS operating system is made; the advantages of the ZigBee protocol compared with the traditional radio technology are comparatively analyzed. At the same time, the node design block diagram based on CC2430 and related development system is provided. In the TinyOS2.x operating system, we analyze CC2430 application program abstract architecture, and on this basis, give the realization process of program design. The research results showed that we achieve an on-line monitoring system based on ZigBee protocol, which has realistic significance of applying ZigBee protocol in wireless sensor network of electrical equipment online monitoring. Based on the above research, it is concluded that the online monitoring system can collect the temperature parameters of the monitored object in real time that it can be widely applied in wireless sensor networks.</span></span></p>

Highlights

  • With the rapid development of China's economy, the demand of national economic life for electricity is increasing

  • We make an experimental study on the application of ZigBee protocol in wireless sensor networks

  • On the basis of analyzing CC2430 application abstract architecture in the TinyOS2.x operating system, we give the realization process of program design, realize a wireless sensor network on-line monitoring system based on ZigBee protocol, and carry out the related experiments

Read more

Summary

Introduction

With the rapid development of China's economy, the demand of national economic life for electricity is increasing. The online monitoring system of electrical equipment commonly used at present needs to transmit the signal collected by each sensor to the data processing center in cable way [1] This approach has many disadvantages: it cannot make contact monitoring of electrical equipment; a large number of cable are difficult to lead out, and it will increase the wiring cost and may damage the insulation; sensor aging or failure will cause the loss of state information amount; sensor configuration change may need to modify the source program of the system software. When the network rate is reduced to 28kb/s, the transmission range can be extended to 134m, having higher reliability.

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call