Abstract

An on-axis time-resolved x-ray pinhole camera has been used on the 20MA 100ns driver Z to image the converging shock wave in dynamic Hohlraum experiments and to image pellet hot spots in inertial confinement fusion implosions. This instrument is susceptible to detecting significant amounts of pinch bremsstrahlung radiation with energies at hundreds of keV and yields of roughly 1kJ. Quite often the bremsstrahlung noise signals have overwhelmed the desired x-ray images. In an effort to eliminate this large source of noise we have incorporated a 6° gold-coated grazing incidence mirror into the time-resolved x-ray pinhole camera system. The mirror reflects soft x rays at energies under 2keV but does not reflect bremsstrahlung radiation at hundreds of keV. We will present data from the instrument without the mirror showing large amounts of bremsstrahlung noise contamination and data with the mirror in the system showing greatly reduced noise levels.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.