Abstract

We analyze the time response of single-grating monochromators for application to extreme-ultraviolet ultrashort pulses. It is shown that time-preserving monochromators can be realized in a single-grating configuration if the number of illuminated grooves is the minimum for a given resolution and the grating time response is close to the Fourier limit for such a resolution. Two different grating configurations are compared: the classical diffraction mount (CDM) and the off-plane mount (OPM). We shown that the CDM is preferred for single-grating monochromators with relatively long time responses, i.e., 100-200 fs, while the OPM is suitable for ultrashort time responses in the 10-50 fs range to realize femtosecond time-preserving monochromators.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.