Abstract

The circular electron-positron collider (CEPC) requires a 3% precision in the measurement of d<i>E</i>/d<i>x</i> to identify long-lived charged particles. However, the measurement of d<i>E</i>/d<i>x</i> has a blind area for each of charged particles of <inline-formula><tex-math id="M8">\begin{document}$\pi / \rm{K}$\end{document}</tex-math><alternatives><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="12-20222271_M8.jpg"/><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="12-20222271_M8.png"/></alternatives></inline-formula>, <inline-formula><tex-math id="M9">\begin{document}$\pi / \rm{P}$\end{document}</tex-math><alternatives><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="12-20222271_M9.jpg"/><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="12-20222271_M9.png"/></alternatives></inline-formula>, and <inline-formula><tex-math id="M10">\begin{document}$\rm{K} / \rm{P}$\end{document}</tex-math><alternatives><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="12-20222271_M10.jpg"/><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="12-20222271_M10.png"/></alternatives></inline-formula>, having transverse momenta of 1 GeV/<i>c</i>, 1.6 GeV/<i>c</i>, and 2 GeV/<i>c</i> respectively. One potential solution is to use a high-precision time-of-flight (TOF) detector with a time resolution of less than 50 ps to fill in the blind area. To address this, we propose a small particle TOF detector that uses small plastic scintillators (<inline-formula><tex-math id="M11">\begin{document}$1 \;\; \mathrm{cm} \times 1 \;\; \mathrm{cm} \times 0.3 \;\; \mathrm{cm}$\end{document}</tex-math><alternatives><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="12-20222271_M11.jpg"/><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="12-20222271_M11.png"/></alternatives></inline-formula>) silicon photomultipliers for readout. In this work, we introduce the construction of the detector and calibrate its performance by using <inline-formula><tex-math id="M12">\begin{document}${ }^{90} \mathrm{Sr} $\end{document}</tex-math><alternatives><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="12-20222271_M12.jpg"/><graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="12-20222271_M12.png"/></alternatives></inline-formula> electron collimators and high-speed waveform acquisition electronics. Using a constant fraction timing method, we find that the time resolution of the detector is about 48 ps, satisfying the CEPC’s requirements for TOF detection.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call