Abstract

In this work, three different techniques, namely time domain reflectometry (TDR), ground penetrating radar (GPR) and electrical resistivity tomography (ERT) were experimentally tested for water leak detection in underground pipes. Each technique was employed in three experimental conditions (one laboratory or two field experiments), thus covering a limited but significant set of possible practical scenarios. Results show that each of these techniques may represent a useful alternative/addition to the others. Starting from considerations on the obtained experimental results, a thorough analysis on the advantages and drawbacks of the possible adoption of these techniques for leak detection in underground pipes is provided.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.