Abstract

Previous finite element analyses of peri-implant stress assumed a bone-implant contact (BIC) ratio of 100%, even though the BIC ratio is known to be approximately 50% or less. However, the recent development of ultraviolet treatment of titanium immediately before use, known as photofunctionalization, significantly increased the BIC ratio, to 98.2%. We used a unique finite element analysis model that enabled us to examine the effects of different BIC ratios on peri-implant stress. A three-dimensional model was constructed under conditions of vertical or oblique loading, an implant diameter of 3.3, 3.75, or 5.0 mm, and a BIC ratio of 53.0% or 98.2%. Photofunctionalization and larger implant diameters were associated with reduced stress on surrounding tissues. Under vertical loading, photofunctionalization had a greater effect than increased implant diameter on stress reduction. Under oblique loading, increased implant diameter had a greater effect than photofunctionalization on stress reduction.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.