Abstract

This paper presents the results obtained from the modeling of the flow and heat transfer in the condenser of the heat pump used for heating the water of a pool, by means of CFD analysis. Using the k-∈ turbulence model its real behavior was described; these data may be useful to propose the improvement of its thermal design. The distributions of temperature, pressure, and velocity, both for the water and the R-410A refrigerant were obtained. The value of the COP of the pump which was 7.6 was found through the results. The experimental value of this variable was 7.32, both values are lower than those offered by the manufacturer of this equipment.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.