Abstract

ABSTRACTIn this study, an improved configuration of lignite-fueled power plant integrated with a two-stage predrying system was proposed. The predrying system mainly consists of two fluidized-bed dryers and an additional feed water heater. Lignite is dried successively in the exhaust gas dryer and steam dryer. With boiler exhaust gas being the heat source of the first stage dryer, waste heat of a fraction of the boiler exhaust gas can be used. The exhaust gas of the second stage dryer was considered to be water vapor and its latent heat can be recovered by the additional feed water heater. The thermodynamic and economic analysis show that with the lignite drying degree being 0.1, 0.2, and 0.3 kg/kg, the power generation efficiency of the proposed power plant is 1.45, 2.12, and 2.81% higher than that of the conventional lignite power plant, respectively. Moreover, the annual net economic benefit will be 1.34, 2.03, and 1.60 M$/a during the lifetime of the drying system. The annual net economic benefit is not necessarily higher with higher power generation efficiency.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.