Abstract
Thermodynamic performance (thermal efficiency and net power output) of a simple subcritical and supercritical Organic Rankine Cycle (ORC) was analyzed over a range of operating conditions for a number of working fluids to determine the effect of operating parameters on cycle performance and select the best working fluid. The results show that for an ORC operating with a dry working fluid, thermal efficiency decreases with an increase in the turbine inlet temperature (TIT) due to the convergence of the isobaric lines with temperature. The results also show that efficiency of an ORC operating with isentropic working fluids is higher compared to the dry and wet fluids, and working fluids with higher specific heat capacity provide higher cycle net power output.New expressions for thermal efficiency of a subcritical and supercritical simple ORC are proposed. For a subcritical ORC without the superheat, thermal efficiency is expressed as a function of the Figure of Merit (FOM), while for the superheated subcritical ORC thermal efficiency is given in terms of the modified Jacob number. For the supercritical ORC, thermal efficiency is expressed as a function of dimensionless temperature.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.