Abstract

Thermocouples on a trench sidewall fronting a flow are fabricated by three-dimensional (3D) photolithography. The conventional thermocouples on the wafer top surface are also fabricated. The performances of these devices are compared. Without the flow inside the microchannel, the thermocouple on the trench sidewall shows the same output voltage as that on the wafer top surface positioned 40 µm from the channel. As a static response, when the microchannel is heated and room-temperature air flows inside the channel, the thermocouple on the sidewall shows a lower voltage. As a dynamic response, when hot air flows inside the channel and replaces the room-temperature air, the thermocouple on the sidewall shows a faster response, increasing its output voltage, and the local temperature of the flow can be measured more precisely.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.