Abstract

The results of an experimental investigation of the thermal transpiration effect (the thermomolecular pressure difference or t.p.d. effect) in a single glass capillary with a length-to-radius ratio of 250 are presented. The temperatures of the gas in the ‘cold’ and ‘hot’ chambers were 273·2°K and 293°K, respectively. A modified relative method has been used. To measure the t.p.d. effect, a capacitance differential digital micromanometer with sensitivity 4·5 × 10−5N/(m2Hz) was used. The gases investigated were He, Ne, Ar, Xe, H2, D2, N2, CO2, CH4 and SF6. It was discovered that in the intermediate flow regime the thermal-creep flow rate does not depend on the (non-isothermal) tangential momentum accommodation coefficient. From the experimental data on the viscous slip flow regime, the Eucken factors and the accommodation coefficients are calculated. For inert gases the Eucken factor is found to be equal to 2·5 within the experimental error, while the accommodation coefficients differ significantly from unity.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.