Abstract
This paper is focused on the determination of thermal parameters (thermal conductivity, thermal diffusivity, and specific heat capacity) of electrical insulating paper from various producers. The transient step-wise method was used to determine all thermal parameters simultaneously. Evaluation was carried out using the differential method. Thermal conductivity was determined from the steady-state temperature response on thickness (corresponding to the number of paper layers), while thermal diffusivity and specific heat capacity was obtained from the dependence of derivative maximum and the corresponding temperature on thickness. Four electro insulating papers differing by composition and thickness: materials NKN (Nomex-Kapton-Nomex), DMD (Dacron-Mylar-Dacron), TFT (TufQUIN TFT 50) and TVAR (ThermaVolt AR) were studied. As a result, the highest value of thermal conductivity (0.17 W/m/K) was determined for the DMD. Remaining three materials possessed thermal conductivity about 0.12 W/m/K. However, differences in specific heat capacity and thermal diffusivity were found to be significantly higher. The lowest specific heat capacity was found for the DMD sample (1200 J/kg/K), while the highest specific heat capacity was found for TVAR sample (4000 J/kg/K).