Abstract

The main objective of this paper is to analyze the thermal performance of direct expansion solar assisted heat pump DX-SAHP(A) by numerical simulation in MATLAB and comparing it with the thermal performance of DX-SAHP(B) which has an optimized collector area and mass flow rate. Optimization is performed for high exergy efficiency using Particle Swarm Optimization (PSO) and Artificial Bee Colony (ABC) optimization technique. The flat plate collector of solar water heater is used as the evaporator with refrigerant (R22).With the optimized value of mass flow rate as 0.055 kg/sec, width as 0.03 m and diameter of riser tubes as 0.021 m the performance of the optimized system has a maximum COP of 6.85 which is greater than the COP of DX-SAHP(A) and the final water temperature of is obtained 100 minutes earlier in the optimized system i.e. DX-SAHP(B) with compressor work less than the system A

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.