Abstract
We measured the thermal neutron cross-section and the resonance integral of the 98Mo(n,γ) 99 Mo reaction by the activation method using a 197Au(n,γ) 198 Au monitor reaction as a single comparator. The high-purity natural Mo and Au metallic foils with and without a cadmium shield case of 0.5 mm thickness were irradiated in a neutron field of the Pohang neutron facility. The induced activities in the activated foils were measured with a calibrated p-type high-purity Ge detector. The necessary correction factors for the γ-ray attenuation ( F g), the thermal neutron self-shielding ( G th) and the resonance neutron self-shielding ( G epi) effects, and the epithermal neutron spectrum shape factor ( α) were taken into account. In addition, for the 99Mo activity measurements, the correction for true coincidence summing effects was also taken into account. The thermal neutron cross-section for the 98Mo(n,γ) 99Mo reaction has been determined to be 0.136 ± 0.007 barn, relative to the reference value of 98.65 ± 0.09 barn for the 197Au(n,γ) 198 Au reaction. The present result is, in general, in good agreement with most of the experimental data and the recently evaluated values of ENDF/B-VII.0, JENDL-3.3, and JEF-2.2 by 5.1% (1 σ). By assuming the cadmium cut-off energy of 0.55 eV, the resonance integral for the 98Mo(n,γ) 99Mo reaction is 7.02 ± 0.62 barn, which is determined relative to the reference values of 1550 ± 28 barn for the 197Au(n,γ) 198Au reaction. The present resonance integral value is in general good agreement with the previously reported data by 8.8% (1 σ).
Paper version not known (
Free)
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have