Abstract
The purpose of this work to estimate oil temperature of hydraulic circuit that leads to affect the efficiency of the system. An expert system is built depending on the available knowledge. This model is generated in a computer program named “Thermal Analysis of Hydraulic System (TAHS)”. The program is used to calculate partial power losses at different components of hydraulic system (pump, motor, valves, cylinder, pipe and fittings). The expert system is capable to estimate oil temperature and power loss with different types of (pumps, oils, circuits and actuator dimension). The chosen experimental conditions are oil flow rate, setting pressure, ambient temperature and duty time. The model is validated experimentally and with other works. The results show an acceptable agreement with average deviation about 2.6% & 6.4% respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Materials Science and Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.