Abstract
Pinch analysis for a sugar plant production capacity 4000 TCD has been carried out to reduce its energy consumptions. The plant has ten evaporators that can be configured to several multiple effect evaporators. It has been running with five-effect evaporator (quintuple) scheme. To maximize energy utilization within the plant, three multiple effect evaporator schemes were evaluated. They are triple effect evaporator, quadruple effect evaporator, and quintuple effect evaporator as the benchmark. The result shows that the quintuple effect evaporator yields the highest energy efficiency by about 10%. Options to achieve such target is to use low pressure steam only for the first effect and to use steam bleeding from the first effect to heat a tertiary juice heater. With this proposed scenario, sugar dryer, wash water RVF unit and wash water HGF unit no longer need external steam for its operation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.