Abstract

In the present work the sugar plant in Sragen, Central Java, Indonesia has ten evaporators that can be configured to five effect evaporators. The optimization ofenergy demand, finding optimum operating condition of LowPressure Steam (LPS), and choosing the best configuration of multiple effect evaporator (MEE) were performed by pinch analysis. In this paper, LPS at 0.4 kg/cm2.G – 1.1 kg/cm2.G were evaluated. The results show that the optimum operating condition of LPS was at 0.9 kg/cm2.G – 1.1 kg/cm2.G. This optimum operating condition enhances the energy saving by about 30% compared to that of existing plant (0.4 kg/cm2.G). The best performance value that can be achieved were Steam on Cane (SOC) by 43.50% and Steam Economy (SE) by 2.1

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.