The absolute length of a single-crystal silicon gauge block was measured by interferometry in the temperature range between 285 K and 320 K and at different air pressures from atmospheric conditions down to 10−5 hPa. From the obtained dataset, the coefficient of thermal expansion (CTE) was determined as well as the compressibility—or the bulk modulus—of single-crystal silicon in consideration of a systematic correction of the refractometer used. As the choice of the underlying model for the evaluation is not unambiguous, a Bayesian model averaging approach was applied to take into account possible model errors in the uncertainty evaluation. The result of the CTE is not only in agreement with the recommended reference data of CODATA, but provides a standard uncertainty of less than 1 × 10−9 K−1, which is less than half the uncertainty stated so far in the relevant temperature range.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.