Abstract
The reliability of adhesive flip chip attachments was studied. A large-area chip with a great number of contacts was attached onto a flexible polyimide substrate using anisotropic conductive adhesive film (ACF). The test samples were manufactured using various bonding forces and the reliability of the assemblies was examined using a thermal cycling test. Two temperature change rates were used in the cycling test to study the effect of the change rate on the observed failure times and modes. The results show that the ACF flip chip attachment of large-area chips with matrix array interconnections is an applicable technique. Furthermore, a significant increase in the reliability of the assemblies was obtained by increasing the bonding force. However, early failures were observed in all the samples, especially in the outermost adhesive interconnections. Failure analysis performed on the samples exhibiting early failures showed signs of adhesive delamination and silicon chip cracking. No clear differences in the results between the two temperature cycling tests used were observed. However, the faster temperature change rate seemed to cause a higher number of early failures.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.