Abstract

The W7-X plasma vessel (PV) is part of the cryostat wall and forms a vacuum and thermal barrier between the hot vessel interior and the superconducting coils. The vessel is thermally loaded from the inside and is actively cooled by numerous cooling water pipes in order to control its temperature.However, due to the complex geometry and large number of different types of ports, the cooling pipes are distributed irregularly with varying distances in between them. So the temperature distribution of the PV becomes quite inhomogeneous even with homogeneous load density, and impermissible temperature hot spots >130 °C may arise. Particularly for the upcoming long pulse operation phase 2 (OP2), it is necessary to know the locally allowed thermal loads on the PV. Therefore, temperature distribution maps for different heat loads from 1 kW/m2 to 12 kW/m2 were calculated in order to determine the corresponding hot spots.The available CAD geometry was not convenient for this extensive and complex analysis; therefore, a simplified shell-beam model was employed to get an approximate temperature distribution, and a correction formula was derived to calculate more accurate values at the positions of interest.In some areas with large distances between cooling pipes, additional copper stripes are welded onto the PV to improve the heat transfer. For these regions local models were built to calculate the temperature distributions, and, in the course of this analysis, to judge the effect of the copper stripes.The calculation results indicate positions to be additionally protected and will be used to determine safe operation limits.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call