Abstract
In the axial fan, the flow pattern for the two dimensional flow in which the fluid flows in concentric cylindrical surface is free vortex. For free-vortex type axial-flow fan, we introduce an expression of circulation, lift and drag coefficient, blade efficiency for impeller and guide vane and show that the Howell's expression of lift is essentially identical with ours. Also we show the expression for manometric efficiency of blade element, whole impeller and guide vane and contra-rotating axial fan and overall manometric efficiency of complete fan including ducts. We can obtain at once the efficiency by these expression.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Transactions of the Japan Society of Mechanical Engineers
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.