Abstract

With the intelligent development of small-caliber ammunition, the overall size of the fuze is compressed. In this paper, a theoretical method-energy statistical method has been proposed according to the MEMS S&A device. Taking the slider mass, micro-spring stiffness, latch mechanism size, and initial offset distance into account, the conversion relationship among each part of energy in the process is obtained. For an existing structure of MEMS S&A device, known parameters are utilized to reverse the overload value at arming condition. The ANSYS/LS-DYNA finite element analysis software is used for simulation analysis, thereby confirming the feasibility of theoretical calculations. Also, theoretical calculation error ε is obtained, which to be 0.7%. Energy statistical method and simulation analysis serve as theoretical references for the design of the MEMS S&A device.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.